To work effectively the vesda vlp detector needs to be supported by a well designed pipe network. Xtralis vlp the xtralis vesda vlp detector is the central element of the xtralis vesda asd product range. Vesda laserfocus vlf500 product guide iii codes and standards information for air sampling smoke detection onorm f3014 onorm f3014, transport times for all tubes including capillaries must not exceed 60 seconds from any hole. The laser is housed in a sealed detector chamber and co ntains no serviceable parts. It gives instructions on installing, wiring and powering. Alert, action, fire 1, fire 2, maintenance, urgent fault and isolate. Vesda laser plus vlp detector the laser plus detector can be used for wide area. The detector works by continually drawing air into sampling holes in a pipe network. The detection of smoke results in the system locating the sector in alert. Vesda vlp the vesda vlp detector is the central element of the vesda asd product range.

It suggests a maintenance schedule and provides instructions on how to service and maintain the different components making up a vesda laser system. The xtralis vesda lcd programmer product guide contains comprehensive information about the features, installation, and use of the lcd programmer. Xtralis vesda xtralis vesda pipe network design guide. Just fill out the contact form, or give us a call at 888 8644362, to get your free, noobligation quote.

To provide a full range of solutions to our customers, intelligent fire offers specialized services related to xtralis vesda very early smoke detection apparatus systems. Available in two models, the vlf250 covers up to 2,500sqft, and the vlf500 covers up to 5,000sqft. A schedule for preventative maintenance is also provided. Vesda vlf vesda aspirating smoke detection notifier. The laserplus incorporates a laser device and is classified as a class 1 laser product that complies. The vlp is classed as a very early warning smoke detector. Like all vesda products it detects fires at the earliest possible stage and reliably measures very low to extremely high concentrations of smoke. It is assumed that people troubleshooting a vesda laser detector are knowledgeable about the local codes and standards. Installation sheet for vesda laserplus and vesdalaserscanner. May 14, 20 if you have any questions regarding the xtralis vsp005 dualstage filter cartridge vesda replacement filter or any other xtralis product please feel free to reach out to us. Proper safety precautions must be taken during tests and maintenance of the products. Ensure that all the precommissioning checks are carried out successfully.

Introduction to vesda laserfocus the vesda laserfocus early warning air sampling smoke detector incorporates world leading. The system can safely compensate for this transient state, allowing for continual operation. The vesda maintenance guide pr ovides information on mainta ining a vesda laser system. The vesda maintenance guide contains a schedule for pipe network maintenance. This guide is written for persons responsible for the maintenance of vesda installations. The vesda laserplus is the flagship of the vesda aspirating smoke detector product line. Introduction to troubleshooting it is possible that occasionally a vesda laser system may indicate certain faults. Very early smoke detection apparatus, vesda, air sampling, uk. Nov 10, 2017 download download vesda laser focus user manual read online read online vesda laser focus user manual vesda laser focus filter change vesda laser plus fault codes vesda vsc user manual xtralis vesda vlf 500 manual vesda vlf250 price xtralis vesda vlp manual vesda vlf 250 troubleshooting vesda admin password mar 29, 2005 accordance with any manual or instructions for use of the product. The vesda maintenance manual contains a schedule for pipe network. Oct 26, 2012 vesda detectors have multilevel warnings and a wide range of sensitivity that does not degrade or change over time, so even minute levels of smoke can be detected before a fire has time to escalate. Individual pipe identification adaptive scan threshold wide sensitivity range laser based smoke detection vesdanet communication 4 alarm levels per sector high efficiency aspirator dual stage air filter easy to replace air filter 7 or 12 programmable relays option autolearn ref.

This vesda product incorporates a laser device and is classified as a class 1 laser product that complies with fda regulations 21 cfr 1040. All proper health and safety precautions must be taken during the. Using unique detection principles, the vlp has an alarm sensitivity range of 0. The laser emits invisible light and can be hazardous if viewed with the naked eye. Vesda laser plus filter vsp 005 vesda laser plus filter vsp 005 availability. Maintenance can be conducted by the original installer, a vesda distributor, or an authorized service contractor. The right side of the window includes a number pad. Vesda system testing and commissioning method of statement. This vesda product incorporates a laser device and is classified as a class 1. This guide is for anyone involved with the design, maintenance and purchasing of the vesda system.

Fda this vesda product incorporates a laser device and is classified as a class 1 laser product that. A zone is broken down into four sectors and air samples are taken from all sectors. This manual is for anyone involved with the design, maintenance and purchasing of. Notifier by honeywell is a manufacturer of fire protection products such as afp2800, afp3030 addressable fire alarm panels, smoke detectors and evacuation systems. The system should not be connected to a power source until all the components have been install ed. Vsp001 vesda handheld programmer fire trade supplies. I am attempting to identify which components i need to allow me to interface with an existing xtralis vlp002 installation using a laptop running the vsc software. Vesda is a very early warning aspirating smoke detector. Unlike the vlp and the vls detectors, the display module cannot be mounted into the. Vesda laser focus vlf detector the vesda laser focus detector is a very early warning smoke detector designed to protect small, businesscritical environments of less than 500 m2 5000 sq. The vesda laserplus is an aspirating smoke detection unit providing very early warning of fire conditions by drawing air samples through an air sampling pipe network. These instructions must be followed to avoid damage to this product and associated equipment. This manual describes the features of the vesda laserfocus, the specifications and functions, installation requirements, commissioning and operation procedures. The status of the detector, and all alarm, service and fault events, are transmitted to.

It gives instructions on installing, wiring and powering up the detector. Ensure the area surrounding the filter is clear of dirt and debris prior to replacement. The laser emits invisible light an d can be hazardous if viewed with the naked eye. This guide introduces you to the vlp features, technical specifications and gives an understanding of its components and their function. Remove all burrs and filings, and place a slight bevel on the pipe end. Notifier manufactures ewis systems, occupant warning and speakers. Vesda by xtralis vesda vlc product guide 12 maintaining and servicing the detector to maintain the vlc detector at its peak performance the maintenance schedule given below should be followed. This vesda product incorporates a laser device and is classified as a class 1 laser product that complies with fda regulations.

The laser is housed in a sealed detector chamber and contains no serviceable parts. An aspirating smoke detector asd is a system used in active fire protection, consisting of a central detection unit which draws air through a network of pipes to detect smoke. The vesda vlp by xtralis is the flagship of the vesda aspirating smoke detector product line. The vesda vlp detector is the central element of the vesda asd product range. The lcd programmer product guide is written for people who are involved in the design, purchase, installation, commissioning, monitoring, maintenance, and management of an xtralis vesda system.

The vlp002 is used for the sole purpose of pulling. Address with a vlp detector lists functions available for accessing and. Vesda vlp laserplus aspirating smoke detector range viking nz. A vesda lunch and learn presentation covers the major design aspects of a revolutionary addressable aspirating system including relevant codes and standards, advanced detection products andor their application in specific markets and case studies. Laserfocus vlf500 product guide vesda filter replacement. Overview the laserscanner is a four air inlet aspirating smoke detector similar to the laserplus but with the added feature of being able to detect the source and spread of a fire by individual pipe identification. The vesda vls performs a scanner valve test when first powered up. Similar to vesda laserplus, however it allows the system to distinguish and identify the pipe carrying smoke, while sampling multiple sectors. Field demo of a vesda xtralis air aspirating smoke detection system in a large data center. Vesda laserplus aspirating smoke detector vlp xtralis. The vesda troubleshooting guide helps understand the faults that may arise from a vesda laser system and how to rectify these faults. Detector is placed in standby disabled, plus aspirator turned off. Inside the vesda vlp, a sample of air is passed into the laser detection chamber. Care must be taken not to split the pipe if a ratchet type cutter is used, particularly at colder temperatures.

Burkert side control 1067 manual vesda laser plus user manual for mac downloaded and installed quickly. Laser based light source configurable alarm levels purposebuilt aspirator 4 inline inlet pipes flow sensor for each pipe inlet lowcost maintenance dualstage filter easy access to filter cartridge recessed mounting description the scanner is similar to the standard vesda laserplus detector, but also in. Similar to the vls214, but is the 12 relay version. This vesda product incorporates a laser device and is classified as a class 1 laser product that complies with fda regulations 21 cfr. Vesda laserfocus aspirating smoke detector vlf the vesda vlf by xtralis is an aspirating smoke detector ideal for small, businesscritical spaces. Vesda vlp laserplus aspirating smoke xtralis xtralis vesda products xtralis. Available in two models, the vlf250 covers up to 250 m2 2,690 sq. All vesda equipment is to be commissioned by personnel who have attended a vesda accreditation course. I see i was unaware anyone would or could sell or the xtralis system would accept, a used filter. Vesda detectors have multilevel warnings and a wide range of sensitivity where minute levels of smoke can be detected before a fire has time to escalate. We sell and service fire extinguishers, fire systems, fire protection equipment. The first stage removes dust and dirt from the air sample before it allows the sample to enter the laser detection chamber for smoke detection. The vesda laserscanner detector will continue to sample from all sectors to monitor the fire growth and maintain full protection.

This vesda product incorporates a laser device and is classified as a class 1 laser product that complies with fda. Laserfocus vlf250 product guide vesda iv contact us codes and standards information for air sampling smoke detection we strongly recommend that this document is read in conjuncti on with the appropriate local codes and standards for smoke detect ion and. The vesda vlf500 detector is a very early warning smoke detector designed to protect small, businesscritical environments of less than 500 m 2 5000 sq. Ultrafine air filtration provides very clean air to protect the optical surfaces inside the detector from contamination. The vlp is classed as a very early warning smoke detector, which means that it detects fire at the earliest possible stage and reliably measures ve. Vesda vlp012 laserplus aspirating smoke detector with programmer and display panels. The laserplus is the core product in the vesda product range. Conditions, user manual and product documents available from xtralis. However, referencing by vesda ensures any external pollution does not interfere with the actual, valid smoke level being detected in the protected space. The detector chamber can detect presence of smoke at very low concentrations. This xtralis product incorporates a laser device and is classified as a class 1 laser.

Inside the vlp, a sample of air is passed into the laser detection chamber. Vesda aspirating smoke detectors buy the critical time needed to investigate an alarm and initiate an appropriate response to prevent injury, property damage or business disruption. This guide is for the standard vesda product range only. Notifier also manufactures digital voice command for mass notification systems. A sample of this air is then passed through a dual stage filter. The sampling chamber is based on a nephelometer that detects the presence of smoke particles suspended in air by detecting the light scattered by them in the chamber. Vesda product manuals for the vesda laserplus, laserscanner. This document ships with the laser plus and the laser scanner. Xtralis product specific manual included with the vesda.

Scope of this manual this manual is intended for installation technicians to be able to install, perform basic power and preliminary device checks for the laserplus detector. It is recommended that you attended accredited vesda training before attempting to troubleshoot problems with a detector. Maintenance can be conducted by the original installer, a vesda distributor, or an authorized service. Faults not applicable to the standard vesda range of products have not been included in this guide. Xtralis vesda vlf250 product guide product manual pdf. This manual describes the features of the vesda laserfocus, the specifications and. Xtralis vesda vlp product guide august 2008 document number. The vesda laserfocus vlf is a very early warning smoke detector designed to protect small, business critical environments. The vesda power supply has been designed to power a single unit to multiple units depending on application needs. Xtralis vesda xtralis vesda pipe network installation guide.

Maintenance can be conducted by the original installer, vesda distributor, or a service contractor. The vesda power supply is capable of providing operating power, including battery backup, for the entire line of vesda by xtralis aspirating smoke detectors. The system should not be connected to a power source until all the components have been installed. This guide is written for those involved with the management, commissioning, maintenance and servicing of vesda laser systems. Vesda laserfocus aspirating smoke detector vlf xtralis. Vesda vlp400 laserplus detector acorn fire security. Prior to carrying out any work or maintenance on the vesda vlf take the necessary steps to. Vesda laser plus 1 pipechannel supported vesda laser scanner 4 pipechannel supported the intelligent interface is compatible with the following simplex facps. Green berets ultralight bug out bag with gear recommendations duration. These systems are ideal for use with modern fire alarm systems, and are perfect for providing smoke detection coverage for sealed voids and other areas with ongoing maintenance issues. Product operation and reliability depend upon proper installation. Prior to carrying out any work or maintenance on the vesda laserfocus take the.